K-13 Spray-On Systems®
Approvals and Ratings
These fire ratings are derived from product tests per ASTM
standards and are used solely to measure and describe properties of
materials and products in response to heat and flame under controlled
laboratory conditions. They are not intended to reflect
hazards presented by these or any other materials under actual fire
conditions. |
 |
| |
Fire Performance Ratings
K-13 has been rated and approved by Factory Mutual Research
Corporation for use in the following categories:
Category I: As an interior finish materail of low fire
hazard (Class I Building Material) over noncombustible surfaces not
requiring automatic sprinkler protection in and of itself.
Category II: As a protective coating to delay the
ignition and reduce the surface burning rate of combustible wood and
cellulosic fiber building materials.
Category III: As a protective coating to delay the
ignition and reduce the surface burning rate of low melting, combustible
cellular plastic building materials and to protect their dimensional
stability for a brief period.
Category IV: As a protective coating for building
structural steel to supplement automatic sprinkler protection in
preventing structural failure temperatures of the steel in high fire
hazard occupancies.
Category V: As a protective coating to the underside of
Class II insulated steel roof deck construction to sufficiently lower
the rate of fuel comtribution from the Class II deck components to
qualify the construction as Class I allowing automatic sprinkler
protection to be omitted where permissible under Factory Mutual
Standards.
|
| |
Surface Burning Characteristics
K-13 has a Class 1, Class A flame spread rating per ASTM
E-84, UL-723, NFPA-255 and UBC-42.
Flame spread - 5
Smoke developed - 5
Underwriter's Laboratories - Ref #R5499
|
| |
One-Hour Fire Wall
Fire Endurance Tests
Wall assemblies tested in accordance with full scale
ASTME-119 including hose stream test. |
| |
|
ASTM Standards Compliance |
| ASTM-C-177 |
Thermal conductivity |
| ASTM E-119 |
Full Scale Fire Wall Test, including Host
Stream Test |
| ASTM E-84 |
Surface Burning Characteristics |
| ASTM C-423 |
Noise Reduction Coefficients |
| ASTM C-523 |
Light Reflectance |
| ASTM E-736 |
Bond Strength |
| ASTM E-859 |
Air Erosion |
| ASTM C-739 |
Moisture Absorption |
| ASTM E-90 |
Sound Transmission Loss |
| ASTM E-413 |
Sound Transmission Loss |
| ASTM E-1042 |
Acoustical Absorption |
| ASTM C-1149 |
Spray-applied Cellulose Insulation |
| Test reports available
upon request |
|
| |
|
Miscellaneous Approvals and Specifications
|
| ICBO - No. 2262 |
| SBCCI - No. 9566 |
| Underwriter's Laboratories - Ref No R5499 |
| Los Angeles - RR-24311 |
| New York - 79-73-SM |
| Dade County - 92-0107.8 |
| Federal Defense Logistics Agency Cage Code - ONJU2 |
| Department of the Navy Guide Specifications - 07218 |
| Corps of Engineers Guide Specifications - CE-201.01 |
| Federal Specification - SS-S-111C |
| Factory Mutual Research - Report Nos 19678, 20399 and
24703 |
| Meets California Bureau of Home Furnishings Standards |
| Resource Conservation and Recovery Act - EPA 40 CFR
Part 248 |
| |
 |